Plate Load Test Report Xls Work |best| Page
: Calculated by dividing the failure load by the plate area.
Your first dial gauge reading is initial reading , not zero settlement. Always calculate Settlement = Current_Reading - Initial_Reading . Your XLS formula should be: =D2-$D$2 (absolute reference to first reading). plate load test report xls work
The heart of your is the data entry sheet. You should record: : Calculated by dividing the failure load by the plate area
You must record the unloading cycle to see the elastic rebound. plate load test report xls work